Skip to main content

Difference Between One Way Slab and Two Way Slab.

One Way Slab Vs Two Way Slab | Difference Between One Way
Slab and Two Way Slab.

One Way Slab.

One way slab is supported on two opposite side only thus structural action is only at one
direction. Total load is carried in the direction perpendicular to the supporting beam. If a slab is supported on all the four sides but the ratio of longer span (l) to shorten span (b) is greater than 2, then the slab will be considered as one way slab. Because due to the huge difference in lengths, load is not transferred to the shorter beams. Main reinforcement is provided in only one direction for one way slabs.

Two Way Slab.

Two way slabs are the slabs that are supported on four sides and the ratio of longer span (l) to shorter span (b) is less than 2. In two way slabs, load will be carried in both the directions. So, main reinforcement is provided in both direction for two way slabs.

Difference Between One Way Slab and Two Way Slab.

There are some basic differences between one way slabs and two way slabs. To clear the

concept of one way and two way slabs a table is shown below.

  1. One way slab: is supported by beams in only 2 sides.
  2. Two way slab: is supported by beams in all four sides.
  3. One way slab: The ratio of longer span panel (L) to shorter span panel (B) is equal or greater than 2. Thus, L/B >= 2.
  4. Two way slab: The ratio of longer span panel (L) to shorter span panel (B) is less than 2. Thus, L/B < 2. 
  5. One way slab: Main reinforcement is provided in only one direction for one way slabs.
  6. Two way slab: Main reinforcement is provided in both the direction for two way slabs.

वन वे स्लैब बनाम टू वे स्लैब | वन वे के बीच अंतर

स्लैब और टू वे स्लैब।

एक तरह से स्लैब।

एक तरह से स्लैब दो विपरीत दिशा में समर्थित है केवल इस प्रकार संरचनात्मक कार्रवाई केवल एक पर है
दिशा। कुल भार सहायक बीम की दिशा में सीधा किया जाता है। यदि सभी चार तरफ स्लैब का समर्थन किया गया है, लेकिन अधिक अवधि (l) से छोटा स्पैन (b) का अनुपात 2 से अधिक है, तो स्लैब को एक तरह से स्लैब माना जाएगा। क्योंकि लंबाई में भारी अंतर के कारण लोड को छोटे बीम में स्थानांतरित नहीं किया जाता है। मुख्य सुदृढीकरण एक तरह से स्लैब के लिए केवल एक दिशा में प्रदान किया जाता है।

दो तरह से स्लैब।

दो तरह के स्लैब ऐसे स्लैब हैं जो चार तरफ से समर्थित हैं और लंबी अवधि (l) से छोटे स्पैन (b) के अनुपात में 2 से कम है। दो तरह से स्लैब में, लोड को दोनों दिशाओं में ले जाया जाएगा। तो, दो तरह से स्लैब के लिए दोनों दिशाओं में मुख्य सुदृढीकरण प्रदान किया जाता है।

वन वे स्लैब और टू वे स्लैब के बीच अंतर।

एक तरह से स्लैब और दो तरह के स्लैब के बीच कुछ बुनियादी अंतर हैं। साफ़ करने के लिए
एक तरह से और दो तरह से स्लैब की अवधारणा को नीचे दिखाया गया है।

एक तरह से स्लैब: केवल 2 पक्षों में बीम द्वारा समर्थित है।
दो तरह से स्लैब: सभी चार पक्षों में बीम द्वारा समर्थित है।

एक तरह से स्लैब: लंबे स्पैन पैनल (L) से छोटे स्पैन पैनल (B) का अनुपात बराबर या 2 से अधिक है। इस प्रकार, L / B> = 2
दो तरह से स्लैब: लंबे स्पैन पैनल (L) से छोटे स्पैन पैनल (B) का अनुपात 2 से कम है। इस प्रकार, L / B <2

एक तरह से स्लैब: मुख्य सुदृढीकरण एक तरह से स्लैब के लिए केवल एक दिशा में प्रदान किया जाता है।
दो तरह से स्लैब: दो तरह के स्लैब के लिए दोनों दिशाओं में मुख्य सुदृढीकरण प्रदान किया जाता है।
Difference Between One Way Slab and Two Way Slab.
Difference Between One Way Slab and Two Way Slab.

Comments

Popular posts from this blog

MACHINE FOUNDATION.

MACHINE FOUNDATION. The design of machine foundation involves careful study of the vibration characteristics of the foundation system. Relevant data for the design and construction of the foundation of machine should be obtained from the manufacturer of the machine , prior to the start design.  All parts of machine foundation should be designed for maxim stresses due to the worst combination of vertical loads, torque, longitudinal and transverse forces, stresses due to temperature variation and the foundation dead load. In case, the foundation layout is partly built up of beam and column construction , straight bars should be provided both at top and bottom of the beams and the spacing of the stirrups should be close. The main foundation block should have the designed thickness and should be reinforced both at top and bottom even if the reinforcements are not required from design considerations. Machine foundations  are special types of  foundations  required fo...

Concrete Mix Design

Concrete Mix Design Concrete mix design is the method of optimally dosing various components of concrete,such as cement, aggregates, water,and additives, to make concrete less costly and will have specific  workability and homogeneity properties in the fresh state and strength and durability in the hardened state. Purpose of concrete mixes The main objective of the dosage of concrete mixes is to make a concrete that has the following characteristics: 1. Satisfy viability requirements in terms of drop to facilitate placement and consolidation. 2. Meets resistance requirements. 3.  Can be mixed, transported, placed and compacted efficiently. 4. Economical to manufacture. 5. Meets durability requirements to withstand the environment in which the structure is expected to serve Mixing ratio procedure Step 1. Calculate the target average compressive strength for the mixing ratio: The target 28-day average compressive strength according to clause 3.2 of IS 10262. ft = fck + 1.65...

EARTH WORK IN EXCAVATION OF FOUNDATION.

EARTH WORK IN EXCAVATION OF FOUNDATION. Earthwork in excavation  in  foundation  trenches or drains not exceeding 1.5m in width and 10sq. m in plan including dressing of sides & ramming of bottom, disposal of surplus  excavated  soil within 50m lead & 1.5m lift. All  excavation  operation shall include  excavation  and getting out the  excavated  matter. Stability of existing structures.   Before starting excavation trial pits should be dug to ascertain the depth and nature of its foundation. Shoring should be used in all cases when the depth of excavation exceeds its distance from the existing structure.  Excavation.   Foundation trenches shall be dug out to the exact width of the foundation concrete and the sides of the trenches shall be left plumb where the nature of soil admits of it. Where the soil is not good and does not permit vertical sides, the sides Fut be sloped back or shored up carefully. No exca...